| Sign In | Join Free | My insurersguide.com |
|
Place of Origin : Guangdong, China
MOQ : 1
Accuracy : ±0.5°C ±2.5%RH
Power : 1.52KW
Protection Class : IP57
Voltage : 220 V, 380 V, 240 V, 110 V
Inner Size : 40×50×40 cm (LY-280), 50×60×50 cm (LY-2150), 50×75×60 cm (LY-2225), 60×85×80 cm (LY-2408), 100×100×80 cm (LY-2800)
Outside Size : 93×155×95 cm (LY-280), 100×148×106 cm (LY-2150), 117×166×91 cm (LY-2225), 140×176×101 cm (LY-2408), 170×186×111 cm (LY-2800)
Volume : 80 L (LY-280), 150L (LY-2150), 225L (LY-2225), 408L (LY-2408), 800L (LY-2800)
Temperature Range : -20°C~150°C (A), -40°C~150°C (B), -60°C~150°C (C), -70°C~150°C (D)
Humidity Range : 20%-98% RH
Fluctuation : ±0.5°C ±2.5%RH
Deviation : ±0.5°C-±2°C ±3%RH(>75%RH); ±5%RH(≤75%RH)
Controller Accuracy : ±0.3°C ±2.5%RH
Wind Cycling : Centrifugal fan-broadband type forced air circulation
Refrigeration Way : Single stage compression refrigeration
Refrigerants : R4O4A USA DuPont environmental protection refrigerant(R23+R404)

Model | LY-280 | LY-2150 | LY-2225 | LY-2408 | LY-2800 | ||||||
Inner Size W×H×D(cm) | 40×50×40 | 50×60×50 | 50×75×60 | 60×85×80 | 100×100×80 | ||||||
Outside Size W×H×D(cm) | 93×155×95 | 100×148×106 | 117×166×91 | 140×176×101 | 170×186×111 | ||||||
Volume (V) | 80 L | 150L | 225L | 408L | 800L | ||||||
Temp and Hum Range | A:-20°C~150°C B: -40°C~150°C C: -60°C~150°C D: -70°C~150°C RH20%-98% | ||||||||||
Function | Fluctuation | ±0.5°C ±2.5%RH | |||||||||
Deviation | ±0.5°C-±2°C ±3%RH(>75%RH); ±5%RH(≤75%RH) | ||||||||||
Controller Analytical Accuracy | ±0.3°C ±2.5%RH | ||||||||||
Wind Cycling Way | Centrifugal fan-broadband type forced air circulation | ||||||||||
Refrigeration Way | Single stage compression refrigeration | ||||||||||
Refrigerator | French Tecumseh | ||||||||||
Refrigerants | R4O4A USA DuPont environmental protection refrigerant(R23+R404) | ||||||||||
Condensing Way | Air-cooled or water-cooled | ||||||||||
Heater | Nickel chrome heating wire heater | ||||||||||
Humidifier | Semi-closed steam and wet | ||||||||||
Water Supplying Way | Automatic cycling water supply | ||||||||||
Standard Accessories | 1 Observe window(double-deck cavity toughened glass), 1 50mm test hole in the left, 1 PL inner chamber lamp, 2 clapboards, 1 bag of wet and dry bulb, 3 fuses, 1 power line. | ||||||||||
Safety device | Non- fuse-switch(compressor overload, refrigerant high low voltage, over-humidity and temperature protection, Protection switch,fuse stoppage warning system | ||||||||||

|
|
Liyi Customized Environmental Chambers Temperature and Humidity Control Cabinet Conditioning Chamber Images |